VPforce Controls

VC

VPforce Controls

Join the community to ask questions about VPforce Controls and get answers from other members.

Join

šŸ“ƒgeneral

šŸ§°support

You can test the internal connections by

You can test the internal connections by probing with a multimeter in diode test mode: put the positive(red) probe on GND go through other pins with the negative(black) one. It should read a diode (~0.5-0.7V) on all pins, otherwise it would indicate a broken internal connection.
No description

Step one is make sure you have the right

Step one is make sure you have the right version. The "release" build (0.1.3) didnt have support for MSFS. Grab the latest from the pinned post in #VPforce-TelemFFB and then do as blave says

Because of the way TelemFFB takes

Because of the way TelemFFB takes control of the spring for all of MSFS, you will need sticky enabled in order for the spring forces and configured force trim in configurator to work. Iā€™ve been playing with implementing a pseudo-native force trim in TelemFFB for MSFS but have run into some challenges and havenā€™t had a chance to run by walmis yet....