lordgufi
RRCRat Rig Community [Unofficial]
•Created by microgiant. on 2/19/2025 in #fix-my-mesh
Leveling a warped Bed Mesh Vcore4 500mm
thats about what my scans look like and i print fine, as long as you're below .500 range is generally the target for the 500's i regularly achieve .380 once the chamber is warm
8 replies
RRCRat Rig Community [Unofficial]
•Created by microgiant. on 2/19/2025 in #fix-my-mesh
Leveling a warped Bed Mesh Vcore4 500mm
you've got the standard 500mm droop in the middle of the gantry, but you've also got the back of the side rails high. not much to be done with the droop across the gantry ( temp fix is to lift up on the gantry while its warm but it will return eventually ) the front to back bit though you need to adjust the height (squareness) of the two rails that go from front to rear of the frame
8 replies
RRCRat Rig Community [Unofficial]
•Created by lordgufi on 2/4/2025 in #ratos-support
Unable to set Enclosure heater temp after a print completes
103 replies
RRCRat Rig Community [Unofficial]
•Created by lordgufi on 2/4/2025 in #ratos-support
Unable to set Enclosure heater temp after a print completes
just wanted to thank you both again, with your help i was able to print PPA-CF zero issues, entire enclosure properly heated with no manual intervention. It. Was. Glorious.
103 replies
RRCRat Rig Community [Unofficial]
•Created by lordgufi on 2/4/2025 in #ratos-support
Unable to set Enclosure heater temp after a print completes
thanks yall, This works and i just configured it wrong.
103 replies
RRCRat Rig Community [Unofficial]
•Created by lordgufi on 2/4/2025 in #ratos-support
Unable to set Enclosure heater temp after a print completes
it makes sense the more i know now but i forgot i set this when i first did everything
103 replies
RRCRat Rig Community [Unofficial]
•Created by lordgufi on 2/4/2025 in #ratos-support
Unable to set Enclosure heater temp after a print completes
while true, it was never clear ( while setting this up ) that the heater temp was what it would set vs the chamber temp
103 replies
RRCRat Rig Community [Unofficial]
•Created by lordgufi on 2/4/2025 in #ratos-support
Unable to set Enclosure heater temp after a print completes
hahahaha Thats the ticket!
103 replies
RRCRat Rig Community [Unofficial]
•Created by lordgufi on 2/4/2025 in #ratos-support
Unable to set Enclosure heater temp after a print completes
which is that macro
103 replies
RRCRat Rig Community [Unofficial]
•Created by lordgufi on 2/4/2025 in #ratos-support
Unable to set Enclosure heater temp after a print completes

103 replies
RRCRat Rig Community [Unofficial]
•Created by lordgufi on 2/4/2025 in #ratos-support
Unable to set Enclosure heater temp after a print completes
.... ??? mine has never done that
103 replies
RRCRat Rig Community [Unofficial]
•Created by lordgufi on 2/4/2025 in #ratos-support
Unable to set Enclosure heater temp after a print completes
by leaky i dont mean there are air gaps, the material i used just transfers heat too well ( 1/4 fiber board for now )
103 replies
RRCRat Rig Community [Unofficial]
•Created by lordgufi on 2/4/2025 in #ratos-support
Unable to set Enclosure heater temp after a print completes
i'm working around a leaky enclosure which the real answer is "fix that" but not in the cards at the moment
103 replies
RRCRat Rig Community [Unofficial]
•Created by lordgufi on 2/4/2025 in #ratos-support
Unable to set Enclosure heater temp after a print completes
its a 1500W heater with a 120 mm fan on it so not really
103 replies
RRCRat Rig Community [Unofficial]
•Created by lordgufi on 2/4/2025 in #ratos-support
Unable to set Enclosure heater temp after a print completes
if i set 80C it will get me to 55C and once the print starts it will easily maintain it with just the bed alone
103 replies
RRCRat Rig Community [Unofficial]
•Created by lordgufi on 2/4/2025 in #ratos-support
Unable to set Enclosure heater temp after a print completes
i can set 35C and the heater will never get the enclosure there...
103 replies
RRCRat Rig Community [Unofficial]
•Created by lordgufi on 2/4/2025 in #ratos-support
Unable to set Enclosure heater temp after a print completes
meaning i'll never be able to print 🙂
103 replies
RRCRat Rig Community [Unofficial]
•Created by lordgufi on 2/4/2025 in #ratos-support
Unable to set Enclosure heater temp after a print completes
i dont want to use that macro because my enclosure will never hit CHAMBER_TEMP due to leaky
103 replies
RRCRat Rig Community [Unofficial]
•Created by lordgufi on 2/4/2025 in #ratos-support
Unable to set Enclosure heater temp after a print completes
i'm trying to manually set the temp after a print has finished not automated 🙂
103 replies
RRCRat Rig Community [Unofficial]
•Created by lordgufi on 2/4/2025 in #ratos-support
Unable to set Enclosure heater temp after a print completes
which is root issue 🙂
103 replies