Toro22
RRCRat Rig Community [Unofficial]
•Created by Toro22 on 9/24/2024 in #fix-my-print
Knocking hotend off track
9 replies
RRCRat Rig Community [Unofficial]
•Created by Toro22 on 9/24/2024 in #fix-my-print
Knocking hotend off track
Bad description, and bad model. It was a simple thin pole used to generate a tree support.
So the issue condenced.
The extruder will accumulate blobs, that deposit on the model , causing the head to hit it at get out of alignment, or knock a tall model over.
My current test model is a 19x12 multiboard, where the blobs are the bother.
I have
Reduced flowrate from calibrated optimal by 20%
Adjusted temp up/down
Calibrated Pressure advance (0.06) and tested 0.04 to see if it makes a difference (No it didnt)
Current tests
Retratraction values 0.2 - 0.4 -0.6, now running 1.0mm (35mm speed)
Retratraction values 0.2 - 0.4 -0.6, now running 1.0mm (35mm speed)
9 replies
RRCRat Rig Community [Unofficial]
•Created by Toro22 on 9/24/2024 in #fix-my-print
Knocking hotend off track
White PETG
9 replies
RRCRat Rig Community [Unofficial]
•Created by Toro22 on 8/27/2024 in #ratos-support
Belt tension - starting point - Vcore 3.0 , with updated toolhead
Thank you all for your answers!
7 replies
RRCRat Rig Community [Unofficial]
•Created by Toro22 on 4/23/2024 in #ratos-support
Klipper reports SHUTDOWN : verify_heater. ##Urgent##
I thank you for helping me !
10 replies
RRCRat Rig Community [Unofficial]
•Created by Toro22 on 4/23/2024 in #ratos-support
Klipper reports SHUTDOWN : verify_heater. ##Urgent##
..... The conector between the thermistor and the cable running from the hot-end-assy, to the control board.. was in a unfortunate postion..in addition..the connecton was .. Not the best...
Now after 2d 16h :
extruder: temp=240.2
extruder: temp=240.5
extruder: temp=240.4
extruder: temp=240.2
extruder: temp=240.1
extruder: temp=239.9
extruder: temp=239.8
extruder: temp=239.8
10 replies
RRCRat Rig Community [Unofficial]
•Created by Toro22 on 4/23/2024 in #ratos-support
Klipper reports SHUTDOWN : verify_heater. ##Urgent##
Update:
I am following the log step by step... (I know.. life required)
I am seeing
temp=239.2
temp=231.4
temp=238
So ... I am doing as suggested... tracing for loose connectons
10 replies
RRCRat Rig Community [Unofficial]
•Created by Toro22 on 4/23/2024 in #ratos-support
Klipper reports SHUTDOWN : verify_heater. ##Urgent##
PID is done, a couple of times.. just in case.
I am seeing no sharp changes in temperature. A loose cable would likely give spikes of temp-0-temp.
Failing sensors can be, however the temp drop occurs after muliple hours, never after just 10-12 hours.
From the logs, there is a temp swing in the first hours of a "normal" 10C or so... Suddely there is a much greater swing..
I have placed a logging device on the heater element cable. Hopefully I can get some data on that to see if there is a mismatch betewen applied power and actual power... But as its a PWM very active element.. my hopes are modest
10 replies
RRCRat Rig Community [Unofficial]
•Created by Toro22 on 2/6/2024 in #fix-my-print
A disasterous bridge...
Thank you , I will test !
3 replies
RRCRat Rig Community [Unofficial]
•Created by Toro22 on 1/8/2023 in #ratos-support
Controller fan on Octopus Pro 446, config . Help please
Thank you
I got it working....
Howling fans tho...two of them
5 replies