Cody
Cody
RRCRat Rig Community [Unofficial]
Created by Cody on 11/29/2024 in #fix-my-printer
V-Core 3.1 Toolhead 1.0 Commissioning Klipper Error
Side note, both fans are now running at full speed still... will need to look into this a bit further.
8 replies
RRCRat Rig Community [Unofficial]
Created by Cody on 11/29/2024 in #fix-my-printer
V-Core 3.1 Toolhead 1.0 Commissioning Klipper Error
Thank you for the assistance. After many rabbit holes, I found the first and second resolutions needed. The first issue was an error in wiring. By following the v-core 4 wiring suggestions for a v-core 3.1 (https://ratrig.dozuki.com/Guide/12.+Electronics/250#s2629) I mixed up the cables between the thermistor and the heater, as they are miss colored in the directions. After resolving the wiring issue the error still occurred, but now showed as negative degrees Celsius. (note - the jumper was implace as suggested for this toolboard) After multiple attempts to override the extruder sensor, the sensor temperature remained sensing excessive heat or negative heat causing Klipper to shut down. The solution in this case was first to fix the wiring, and then followed by updating Ratos v2.1. After flashing my Rasp Pie and going through the configuration options setup, the extruder reads normal ambient temperature now.
8 replies
RRCRat Rig Community [Unofficial]
Created by Cody on 11/29/2024 in #fix-my-printer
V-Core 3.1 Toolhead 1.0 Commissioning Klipper Error
Thanks for the initial message. I am using v2.0.2 currently. In the printer.cfg hotend selection, I have uncommented [include RatOS/hotends/rapido.cfg]. Is there another place where I need to change the config?
8 replies