Rares09
TTyperactive.xyz
•Created by Rares09 on 2/27/2025 in #🛟-help
Corne 6 with premium case - row no longer works after charging
Hello! After reading through the posts, I believe I'm also experiencing the ESD issue when charging my Corne keyboard with the premium case. This has happened to me twice on the left half of my Corne, with two different nice!nano controllers.
The first time, the middle row stopped working, and the second time, it was the bottom row. I've debugged the issue using a multimeter and confirmed there is continuity between the switches and the pins. I also tried shorting the offending row pin with a few column pins, but nothing registered.
In both instances, the row stopped working immediately after I disconnected the USB cable.