Move out of range on mesh

my config forced me to make change that induce other problem latter as this one: i run a euclid probe with a phaetus volcano so i needed a custom doc and bracket to go around the volcano duct, and doing this the bracket was going to collide with the frame on the x axis, it was sticking further than the endstop so i moved the endstop out 7mm. and so i overide the x max range to 490 instead of 500 (+3 mm for piece of mind). but when running a mesh the combination of the probe big offset (-45 x an -5 y) and reduce X range throw me a : "Move out of range: 509.960 25.000 5.000 [0.000]" what would be the smart way of solwing that ? reprinting a duct and mount or trying to overide the mesh ?
3 Replies
lillian
lillianOP2y ago
No description
blacksmithforlife
Did you adjust your slicer to now only have a max of 490?
lillian
lillianOP2y ago
Yes i did I think it is due to the mesh macro i tryed to look around the macro to find a way of overiding it but as the macro to work on all printer are based of variable i am kind off over my head i will try to go the harware way to fix it hi i re disgned the pieces and all work fine know