RatOS 2.1 Euclid on mellow Fly SHT42 not working

I'm new to the ratOS firmware. I'm current in the process of setting up a new printer with ratos on it. while my other once are being controlled by RRF so I'm a bit new to the entire klipper ecosystem. I'm currently at the point that my axis move, heaters work and I can home x and y. however I'm having issues with my euclid probe. I connected everything up. I'm using the pb1, 5v and grd pins from the sht42 same as shown in the wiring diagram. I've also verified with a dmm that the signal and ground are connected to one another when the probe is deployed. and when I press the switch the connection gets broken. so all that seems to work as it should. However if I check the probes in the system tab I see all of them are open. Z/probe as well. no matter if I attach the probe press the switch or detach the probe it always stays open. anyone have a clue what could be happening?
2 Replies
blacksmithforlife
That tab doesn't dynamically update, did press the button to check the state while having the probe open/closed?
mhermans
mhermansOP6d ago
Yea i did. I ended up, grabbing a dupont 1 to 1 female wire and checking the signal pins that way end figured out that there is something wrong with PB1 on my board. PB2 and pc15 did behave as expected. So I ended up changing the probe_pin value in the ratos config to pb2