Issue: pin heater_bed_heating_pin is an alias for PB2
Typically I can solved this on my own this one is giving so much trouble. I installed 2.1 RC1 and i cannot resolve it.
I moved some of my older config parts over and I used a unified sensorless homing file as i did in 2.0.
Not sure where to go from here
10 Replies
Why are you using an old RC?
update everything, then post debug-zip (download from sidebar in configurator)
on the release candiate 2 now, and still seeing this same issue, prior to that i had the PB11 referenced so i check via discord search and some solved it used EXP2_3 which fixed it
Ah, i see the Manta E3EZ implementation is buggy
your EXP2_3 isn't actually a fix
it's equally as wrong it just doesn't complain (yet)
well push a fix in a second
Okay I undid it
CB1 has terribly buggy wifi at least in my case. Hosts ratos wifi for like 15 seconds and poof. I got a better antenna, now so tj was using rc1 as it worked okay somehow.
Solution
fix pushed
(refresh update manager in mainsail and update RatOS)
This error is because your config files are using aliases but RatOS.cfg is not, and you're attempting to assign the bed heater pin to something that is not the bed heater. (it's mostly the latter. aliases are fine if you're not using the same pin for more than one purpose)
well, nothing changed with RC1 to RC2 in that regard. But yes, the CB1 wifi has always been terrible
Damn dude you are a software wizard
Thank you, I can actually see each controllers resources instead of an error box with just the host resources