Hotend thermistor reading 129c at room temp

I'm using the 42 v1.2 toolboard and the Rapido that comes with the V4 kit. As near as I can tell I have everything selected correctly but the I still get an incorrect reading. I have the jumper in place for the enhanced temp reading as instructed in the build guide. Can't figure out what I'm doing wrong...
4 Replies
Mr_Phelps_VCore_4.0_500
Mr_Phelps_VCore_4.0_500OP•4mo ago
With the jumper off it reads 159c... 😩
TheTik
TheTik•4mo ago
drop your printer.cfg in here you don't want to bother with the "enhanced" temp reading. There are issues I can't recall off the top of my head about using the MAX chip. And your temp being off is 99% of the time the wrong thermistor. Which rapido do you have? It might have the thermistor type on heatshrink on the cables coming from it.
Mr_Phelps_VCore_4.0_500
Mr_Phelps_VCore_4.0_500OP•4mo ago
Not at the printer, will check tomorrow. Thanks for the help! I checked the Rapido and it has a PT1000 RTD. Changed this in RatOS.cfg and it now reads 159.3c at ambient. The RTD checks out at ~1.1k ohms at the pins. So the crimps are good. Wondering if this could be a bad toolboard? Found the wrong thermistor in one of the config files. Now they should all say PT1000. I think I may redo the configurator again as now the cooling fan is running when it shouldn't be. 😕 Re-did the configurator just to make sure it is the same everywhere. Now everything is reporting the correct temps.
TheTik
TheTik•4mo ago
woot!

Did you find this page helpful?