Last RatOS.cfg issue

After updating to v2.1.0-RC1-273-gbc132c38, the stepper motor can't move for homing. I reverted back to the old RatOS.cfg and its working again. I went to see what changed and i think the addition of "Sense_resistor: 0.022" to X and Y steppers is the cause. I'm running TMC5160 with 48v on X & Y. I have attached two files. Ratos.new.cfg is the bad one and RatOS.cfg is the good one.
Solution:
You are correct .. I picked the wrong one 😅
Jump to solution
7 Replies
Yathani
YathaniOP•6mo ago
miklschmidt
miklschmidt•6mo ago
In that case you've picked the wrong drivers in the hardware configurator
BTT TMC5160T Plus v1.0
These are external high amperage drivers. Those are probably not the ones you have 🙂 The reason you've gotten issues after the update is because a bug has been fixed. Previously the sense_resistor values were only emitted when a tuning preset had been matched, leading to very bad consequences for these high amperage devices (overcurrenting with no warning).
miklschmidt
miklschmidt•6mo ago
This is the BTT TMC5160T Plus v1.0
No description
miklschmidt
miklschmidt•6mo ago
My guess is you're using these
No description
miklschmidt
miklschmidt•6mo ago
BTT TMC5160T Pro
Solution
Yathani
Yathani•6mo ago
You are correct .. I picked the wrong one 😅
Yathani
YathaniOP•6mo ago
thank you 🙂

Did you find this page helpful?