pa12 cf15 after filament change mid print bad quality

hello today i have printed a Part of pa12 cf and the First Spool who was printed nearly perfect. After the first spool I load the second spool of pa12 cf (fresh opened spool dryed 6h on 70celcius) and I get instantly bad quality on my print so I stop the print. Do anyone have an idea what reason it has? Thanks
6 Replies
Achi447
Achi4479mo ago
what type of nozzle are you using? had a similar thing happen. I took the whole printer apart and in the end the nozzle was just bad
Retflux
RetfluxOP9mo ago
0.6 phaetus ph tungsten Carbide Nozzle. I think this isnt the problem of this issue because it immediately happened after loading the new pool mid print
Achi447
Achi4479mo ago
ok still worth a try tbh. i also had a hardened steel nozzle and it happened from one spool to the next
Retflux
RetfluxOP9mo ago
Some other picture from closer
No description
Achi447
Achi4479mo ago
ok mine didnt look like this
Retflux
RetfluxOP9mo ago
The issue was the Nylon cf wasnt dry enough. After more then 24h drying it Prints Perfect again.
Want results from more Discord servers?
Add your server