MCU Protocol Error after updats

I ran bunch of updates today and now getting the following error message. I did grab the firmware for my Skr2 and loaded but didn't help. It seems I am on V11 of Klipper and need to go to 12? Klipper reports: ERROR "MCU Protocol error This is frequently caused by running an older version of the firmware on the MCU(s). Fix by recompiling and flashing the firmware. Your Klipper version is: v0.12.0-114-ga77d0790-dirty MCU(s) which should be updated: mcu: Current version v0.11.0-219-g645a1b83 rpi: Current version v0.12.0-114-ga77d0790 Up-to-date MCU(s): <none> Once the underlying issue is corrected, use the "RESTART" command to reload the config and restart the host software. mcu 'mcu': Command format mismatch: query_adxl345 oid=%c rest_ticks=%u vs query_adxl345 oid=%c clock=%u rest_ticks=%u Not really sure how best to upgrade? SSH in to my pi and then what? Thanks (logs attached)
12 Replies
blacksmithforlife
blacksmithforlifeβ€’10mo ago
ahh, looks like there is only partial support for this board https://os.ratrig.com/docs/boards/btt/skr-2-429 and so you have manually flash it again
blacksmithforlife
blacksmithforlifeβ€’10mo ago
No description
psoldo
psoldoOPβ€’10mo ago
yea thanks. I' ve done this in the past and thought I did so today but didn't seem to work. I'll read through and see if that helps. oh so I need to reload RatOS all ovef again? @blacksmithforlife πŸ‡ΊπŸ‡Έ thank you so much. I'm back up and running. Funny in the past I was able to grab the firmware file for my skr2 in mainsail but it had the older version. I guess this is the way forward. Worked really well even for a beginner like myself. Too bad this kit contained this board where you need to take these extra steps but not too hard. I'll save the link you posted for future.
miklschmidt
miklschmidtβ€’10mo ago
No definitely not πŸ˜„
psoldo
psoldoOPβ€’10mo ago
Ha this newer process just works so smoothly. Nice work. πŸ‘
miklschmidt
miklschmidtβ€’10mo ago
Thank you!
etotheipi
etotheipiβ€’5mo ago
Hi, I have the exact same error, but I'm using the BTT Octopus Pro 446, which shouldn't have a support issue (version numbers slightly different but otherwise error is identical).
MCU Protocol error

This is frequently caused by running an older version of the
firmware on the MCU(s). Fix by recompiling and flashing the
firmware.

Your Klipper version is: v0.12.0-267-g12cd1d9e-dirty
MCU(s) which should be updated:
mcu: Current version v0.11.0-200-g7511151a
Up-to-date MCU(s):
<none>

Once the underlying issue is corrected, use the "RESTART"
command to reload the config and restart the host software.

mcu 'mcu': Command format mismatch: query_adxl345 oid=%c rest_ticks=%u vs query_adxl345 oid=%c clock=%u rest_ticks=%u
MCU Protocol error

This is frequently caused by running an older version of the
firmware on the MCU(s). Fix by recompiling and flashing the
firmware.

Your Klipper version is: v0.12.0-267-g12cd1d9e-dirty
MCU(s) which should be updated:
mcu: Current version v0.11.0-200-g7511151a
Up-to-date MCU(s):
<none>

Once the underlying issue is corrected, use the "RESTART"
command to reload the config and restart the host software.

mcu 'mcu': Command format mismatch: query_adxl345 oid=%c rest_ticks=%u vs query_adxl345 oid=%c clock=%u rest_ticks=%u
Annoyingly, there seems to be acknowledgement of this issue on the the 446 config page, but the link there doesn't work. It looks to be a link back to RatOS/mainsail, which just takes me back to this page. There is a directory in my machine tab for firmware_binaries but it's looks last updated May 18, 2023. So that's probably not the binary I need to flash.
etotheipi
etotheipiβ€’5mo ago
No description
etotheipi
etotheipiβ€’5mo ago
Should I just reload RatOS from scratch? Not excited about that, but i can
blacksmithforlife
blacksmithforlifeβ€’5mo ago
please start your own post
etotheipi
etotheipiβ€’5mo ago
Okay, I apologize, thought it would be better to keep it together
Want results from more Discord servers?