Unknown command:"PROBE_CALIBRATE"
Trying to go through the commissioning guide. I have reached the step for the z offset, but when I enter the probe_calibrate command i get an unknown command error. I have no idea how to fix this so I am currently stuck.
12 Replies
Upload your printer.cfg please
adverse-sapphireOP•12mo ago
Here you go.
optimistic-gold•12mo ago
so you're using a beacon?
adverse-sapphireOP•12mo ago
Yes
optimistic-gold•12mo ago
where did you define the probe connection/pin?
adverse-sapphireOP•12mo ago
The beacon connects via USB. It has it's own .cfg. The beacon is working. The problem I am having is the probe-calibrate command is not working.
optimistic-gold•12mo ago
sorry, never used a beacon before
so you have to run probe_calibrate and BEACON_CALIBRATE?
adverse-sapphireOP•12mo ago
Not sure. I'll have to go read the docs again.
optimistic-gold•12mo ago
https://docs.beacon3d.com/quickstart/
doenst look like you use probe_calibrate
Beacon (everything is already installed, just connect it and run BEACON_CALIBRATE)
[include RatOS/z-probe/beacon.cfg]
from your printer.cfg
adverse-sapphireOP•12mo ago
OK. Thanks for pointing me in the right direction. It's been a while since I first set this up.
optimistic-gold•12mo ago
looks like beacon_calibrate is the equivalent of probe_calibrate as thats where you get your z-offset
adverse-sapphireOP•12mo ago
Yep. That was it. Thanks again.