Unknown command:"PROBE_CALIBRATE"

Trying to go through the commissioning guide. I have reached the step for the z offset, but when I enter the probe_calibrate command i get an unknown command error. I have no idea how to fix this so I am currently stuck.
12 Replies
blacksmithforlife
Upload your printer.cfg please
afraid-scarlet
afraid-scarletOP16mo ago
Here you go.
exotic-emerald
exotic-emerald16mo ago
so you're using a beacon?
afraid-scarlet
afraid-scarletOP16mo ago
Yes
exotic-emerald
exotic-emerald16mo ago
where did you define the probe connection/pin?
afraid-scarlet
afraid-scarletOP16mo ago
The beacon connects via USB. It has it's own .cfg. The beacon is working. The problem I am having is the probe-calibrate command is not working.
exotic-emerald
exotic-emerald16mo ago
sorry, never used a beacon before so you have to run probe_calibrate and BEACON_CALIBRATE?
afraid-scarlet
afraid-scarletOP16mo ago
Not sure. I'll have to go read the docs again.
exotic-emerald
exotic-emerald16mo ago
https://docs.beacon3d.com/quickstart/ doenst look like you use probe_calibrate Beacon (everything is already installed, just connect it and run BEACON_CALIBRATE) [include RatOS/z-probe/beacon.cfg] from your printer.cfg
afraid-scarlet
afraid-scarletOP16mo ago
OK. Thanks for pointing me in the right direction. It's been a while since I first set this up.
exotic-emerald
exotic-emerald16mo ago
looks like beacon_calibrate is the equivalent of probe_calibrate as thats where you get your z-offset
afraid-scarlet
afraid-scarletOP16mo ago
Yep. That was it. Thanks again.

Did you find this page helpful?