RatOS update

Just updated RatOS and I’m getting this error on homing “ TMC 'stepper_y' reports error: DRV_STATUS: 801a0090 s2vsa=1(ShortToSupply_A!) olb=1(OpenLoad_B!) cs_actual=26 stst=1 Once the underlying issue is corrected, use the "FIRMWARE_RESTART" command to reset the firmware, reload the config, and restart the host software. Printer is shutdown” Has anyone any ideas? Cheers guys
3 Replies
miklschmidt
miklschmidt2y ago
Your wiring on stepper Y is bad.
triumphdave
triumphdaveOP2y ago
Thanks for prompt reply. That’s a bit of a coincidence as I have just updated. I will check it tomorrow thanks. 👍🏻
triumphdave
triumphdaveOP2y ago
I think this was the problem. Connector burnt out on stepper plug. Took a while to find it and a bit of a coincidence it shorted at the same time as the RatOS update.