Probe triggered prior to movement
It was starting to do the bed leveling sequence. Then it stopped and gave this error. Probe triggered prior to movement. Confused on what's wrong since it was printing fine before.
11 Replies
molecular-blueOP•2y ago
molecular-blueOP•2y ago
#v-minion
Your probe is already registering the bed. Probably a wiring issue, verify that it is still working correctly
molecular-blueOP•2y ago
Endstop z still triggered after retract
I checked all the wires everything looks good. I'm still getting an error message
Do you think it could be because of the probe broke?
how did you check the wiring? Did use the query endstops with and without metal near the probe to verify it is working?
https://www.klipper3d.org/Config_checks.html#verify-endstops
molecular-blueOP•2y ago
I did. And it still wasnt working. I tried a lot of different ways and it still didn't work. I am just going to replace it with a better sensor.
I ordered the same one prusa uses. I figured it might be the wiring but for the cost and my time rip it out and replace it with something better.
High Quality P.I.N.D.A V2 PINDA Sensor Auto Bed Leveling Sensor Probe 4PIN Compatible with Prusa i3 MK3 MK2.5 MK3S MK2.5S 3D Printer
Pinda 2 is inferior to the superpinda. The superpinda that ratrig sells is exactly the same as the current sensor prusa sells
molecular-blueOP•2y ago
Oh, so superpinda? Does it matter much? my goal with getting it is to swap it and see. For a trouble shooting.
Yes, unless you like having a probe affected by temperature
molecular-blueOP•2y ago
What about Beacon surface scanner?
Also thanks I'm going to get the super. I need to order from Fabreeko
I personally have never used it, but I have heard good things