Rapido UHF can 't reach more than 226 °C
Another day another problem
I have a Rapido Plus UHF with a heater up to 350°C, connected to the EBB36 board. When trying to do pit tuning the maximum temperature as it gets is 226°C then to the message "pid_calibrate interrupted".
Up to 180 ° C, the heating slides like crazy but drops drastically.
Anyone have an idea what's wrong
Below is my configuration.
[extruder]
heater_pin: can0:HE0
sensor_pin: can0:TH0
sensor_type: MAX31865
sensor_pin: can0:PT100_CS
spi_bus: spi1
rtd_reference_r: 430
#pullup_resistor: 4700
min_temp: 0
max_temp: 350
max_extrude_only_distance: 200
nozzle_diameter: 0.4
min_extrude_temp: 170
pressure_advance: 0.03
rtd_num_of_wires: 2
control: pid
pid_kp: 56.652
pid_ki: 2.861
pid_kd: 280.431
[firmware_retraction]
retract_length: 0.5
3 Replies
Rapid Plus is a PT1000 not a PT100
PT1000
its only the name