MDW Magbed Mesh
Anyone know how to setup faulty regions? I have messinga round for the past week but can't figure it out. I entered the below info the printer.cfg to test out the first spike, but klipper crashes after the scan completes. Appreciate the help!
[bed_mesh] #exclude zones for magnets
speed: 120
horizontal_move_z: 5
mesh_min: 20, 30
mesh_max: 470, 462.5
probe_count: 40, 40
faulty_region_1_min: 20.0, 85.4
faulty_region_1_max: 54.6, 129.8

2 Replies
Finally figured it out, found this solution on the github....
https://github.com/Rat-OS/RatOS/issues/166
GitHub
RatOS Internal error on command:"BED_MESH_CALIBRATE" when using fau...
What happened When attempting to set faulty_region in a printer.cfg under a custom [bed_mesh] upon completing a BED_MESH_CALIBRATE the printer shuts down with the following error: Internal error on...
Here is my mesh now with faulty regions.