Sensor 'extruder' temperature 45496.282 not in range - Differences in Rapido 2 Hotends?
Hi!
I had to replace my VCore 4s Rapido 2 UHF Hotend and now ended up with the error "Sensor 'extruder' temperature 45496.282 not in range 0.000:350.000"
This might be down to potential differences in the Rapido 2 Hotends. I bough another UHF, its thermistor looks different tough, its screwed in.
The more I am trying to read into it, the more confused I get about what Rapido 2 might be the correct one and if this is my issue in the first place.
I attached pictures.
The one with the screw in thermistor is the one I bought
Thank you very much for your help!


3 Replies
Either wrong configuration or missing the jumper in the toolboard.
Both are PT1000
Hey!
I am very sorry it took me so long to get back to this topic.
I found that the issue was, that I needed to buy the Rapido PLUS 2 UHF Hotend.
The Regular, non plus version, does feature a 104NT thermistor.
So, even though the manual speaks of the Rapido Hotend 2 hotend, the PLUS is required - or, at least a double check it does in fact feature a pt1000 thermistor 🙂
Not at all. A regular rapido can be used. You just need to configure it correctly by selecting the nt on the temp sensor and remove the jumper