Bed not heating - heater_bed not heating
Hello everyone, my bed was working smoothly. Late night I was burning ASA so my bed was working between 110-105C. I put it to heat and then this message appeared.
I checked other posts and probably it's the thermal fuse. So I have two questions:
1) What are the specs of the thermal fuse, just in case I have to change it?
2) Can I, instead of using a thermal fuse, use a thermal switch? Because if it keeps going off (I plan to work with Nylon a lot) I don't want to keep changing fuses.
I'll perform some checks in a few hours to confirm it's the thermal fuse, but I'm almost sure it is.
Thanks in advance!
1 Reply
Okay so the SSR Relay was bad, even I wasn't sending signal to the bed there was voltage on it. Ordered 2 SSRs. Also the thermal fuse was blown so also I have to change them. Anyone knows what kind of terminals were used to crimp them?