Wrong hotend temperature

Hi all, I just finished building my VCORE 3.1 300mm standard kit (no modifications). When I'm on ratos.local, the hotend temperature is at 159°C but it should be the room temperature and when I give a target (for exemple 200°C) the temperature decrease and I get an error. I searched on ratrig docs but can't find my answer, can you help me please ?
Solution:
Sorry, I found the solution, I added sensor_type: PT1000 in the [extruder] section of printer.cfg and it works 🙂
Jump to solution
1 Reply
Solution
Baptno
Baptno9mo ago
Sorry, I found the solution, I added sensor_type: PT1000 in the [extruder] section of printer.cfg and it works 🙂
Want results from more Discord servers?
Add your server