Stowable probe docks and homing: toolhead runs into dock when homing if in line with probe dock
I have a PCB_Klicky installed on my V-Core 3.1, with a dock at the front-left corner of the printer. If my toolhead is in line with the dock, and running the default homing procedure, the toolhead will run into the dock. I have a custom probe implementation for the PCB_Klicky, but it inherits from the official klicky config (config attached).
This only really happens when I've been messing with the toolhead and have it at the front of the printer, but still, something I'd like to never have to worry about.
I've gotten around this by overriding the "ratos_homing" macro and swapping the "x" and "y" if statements so Y is homed first, but is there a better way to do this? I'd rather not override the macro and feel like I may be missing something in how RatOS implements stowable probe logic since this seems like a situation others would run into.
Thanks in advance!
0 Replies