MCU instant shutdown

I have attached my Kipper log and also a screenshot. At first I thought this was just a thermostat but after replacing all of them and their wires it has to be something else.
6 Replies
Helge Keck
Helge Keck2y ago
check your thermistor cables they are eprobalby not connected or in the wrong connector on the board
jolly-crimson
jolly-crimsonOP2y ago
I removed all thermistors and same shutdown. Then I replaced all of them and same shutdown. I have four in the machine too. One for the bed. two for the chamber. one for the hottend.
Helge Keck
Helge Keck2y ago
this is a expected behaviour, thats not how you chck it your error isnt a bug or someting, its a klipper safety feature one of your thermistors, or thermistor related configuration is wrong
jolly-crimson
jolly-crimsonOP2y ago
Which of my thermistors do I need to check in configeration?
Helge Keck
Helge Keck2y ago
i suggest to outcomment all unneded thermistors you have configured, start only with hotend and bed thermistor makes it easier some people swap the bed thermistor and heater cable so its a good idea to check if you swapped it accidentaly
jolly-crimson
jolly-crimsonOP2y ago
Ok using outcomments I have isolated it to the hottend thermistor. Time to swap the wire again lol Thank you for stearing me in the right track. I am back to printing. Well right now I am doing imput shaper tests. RatOS makes this so easy.
Want results from more Discord servers?
Add your server