would like to record an analog signal of 70mghz frequency min, how do i proceed, the time is max 16

Hi team, i would like to record an analog signal of 70mghz frequency min, how do i proceed, the time is max 16 min of recording
Solution:
As per Nyquist criterion, your sampling frequency must be twice of measuring frequency, so your signal is 70 MHz, so fsample must be 140MHz, in this case you need ADC with 250Ms/s atleast, and depends on your measuring instrument memory you will have to transfer the measured data to larger memory multiple times in 16 mins as DSOs does not have large memory, this changes with resolution of ADC. Lower resolution lower data.
Jump to solution
4 Replies
onky
onky7mo ago
What kind of setup do you have? LabView with NI hardware might help. Or do you want to build your own hardware for this?
youcef_ali
youcef_ali7mo ago
Yes, i have nothing starting from zero
onky
onky7mo ago
So I assume, you want design your own electronics.
Solution
onky
onky7mo ago
As per Nyquist criterion, your sampling frequency must be twice of measuring frequency, so your signal is 70 MHz, so fsample must be 140MHz, in this case you need ADC with 250Ms/s atleast, and depends on your measuring instrument memory you will have to transfer the measured data to larger memory multiple times in 16 mins as DSOs does not have large memory, this changes with resolution of ADC. Lower resolution lower data.
Want results from more Discord servers?
Add your server